TH-GC0424PM2-Z400W Layer2 Layer2 Ethernet Switch 4xGigabit Combo(RJ45/SFP) 24×10/ 100/ 1000Base-T PoE
Gigabit Layer 2 PoE Switch e laoloang ke Green Energy-Saving PoE Switch e ikemetseng. Ka IC ea boleng bo phahameng le e potlakileng ea Network le PoE Chip e tsitsitseng ka ho fetisisa, lipalangoang tsa PoE li kopana le IEEE802.3af 15.4w le IEEE802.3at 30w. Moetso ona o ka fana ka khokahano e se nang moeli bakeng sa 10/ 100/ 1000M Ethernet, 'me boema-kepe ba motlakase ba PoE bo ka khona ho bona le ho matlafatsa lisebelisoa tse tsamaisoang tse lumellanang le IEEE802.3af/at standards. Lisebelisoa tsa Non-PoE li tsamaisoa ka likhoka 'me li fetisa data feela.
● Fetisetsa data bakeng sa lik'hamera tse behang leihlo la marang-rang
● 24x 10/ 100/ 1000Mbps Auto-sensing PoE Ports, 4x 10/ 100/ 1000Mbps Combo Ports, 1x Console Port
● Tšehetsa IEEE802.3/IEEE802.3i/IEEE802.3uIEEE802.3ab/IEEE802.3z, IEEE802.3af/at, lebenkele-le-pele
● E lumellana le IEEE802.3at (30W)le IEEE802.3af (15.4w)
● Boema-kepe ba Ethernet bo tšehetsa 10/ 100/ 1000M tse feto-fetohang le mesebetsi ea PoE
● Sesupo sa phanele se beha leihlo boemo le ho thusa tlhahlobo ea ho hloleha
● E ts'ehetsa netefatso ea boema-kepe ba 802.1x, ts'ehetsa netefatso ea AAA, tšehetsa TACACS+netefatso
● Litlhophiso tsa ts'ireletso ea DOS, li-setting tsa ACL
● Tšehetsa WEB, TELNET, CLI, SSH, SNMP, tsamaiso ea RMON
● Tšehetsa PoE Power Management le PoE Watchdog
● Tšireletso ea Lehalima: Mokhoa o Akaretsang 4KV, Mokhoa o fapaneng oa 2KV, ESD 15KV
| P/N | Tlhaloso |
| TH-GC0424PM2-Z300W | Layer2 Managed Ethernet Switch 4xGigabit Combo(RJ45/SFP) 24×10/ 100/ 1000Base-T PoE Port, Phepelo ea Matla ka Hare 52V/5.76A, 300w |
| TH-GC0424PM2-Z400W | Layer2 Managed Ethernet Switch 4xGigabit Combo(RJ45/SFP) 24×10/ 100/ 1000Base-T PoE Port, Phepelo ea Matla ka Hare 52V/7.69A, 400w |
| I/O Interface | |
| Kenyeletso ya Matla | Kenya AC 110-240V, 50/60Hz |
| Boema-kepe bo tsitsitseng | 24 x 10/100/1000Mbps PoE Port |
| 4 x 1000M Combo (RJ45/SFP) Port | |
| 1 x RJ45 Console Port | |
| Tshebetso | |
| Ho Fetola Bokhoni | 56Gbps |
| Phello | 41.66Mpps |
| Pakete Buffer | 4Mb |
| Memori ea Flash | 16MB |
| DDR SDRAM | 128MB |
| Aterese ea MAC | 8K |
| Sebopeho sa Jumbo | 9.6Kbytes |
| Lisebelisoa tsa VLAN | 4096 |
| Mokhoa oa ho fetisa | Boloka le ho ea pele |
| MTBF | Lihora tse 100000 |
| Standard | |
| Protocol ea marang-rang | IEEE 802.3: Ethernet MAC Protocol |
| IEEE 802.3i: 10BASE-T Ethernet | |
| IEEE 802.3u: 100BASE-TX Fast Ethernet | |
| IEEE 802.3ab: 1000BASE-T Gigabit Ethernet | |
| IEEE 802.3z: 1000BASE-X Gigabit Ethernet (fiber ea optical) | |
| IEEE 802.3az: Ethernet e sebetsang hantle ka matla | |
| IEEE 802.3ad: Mokhoa o tloaelehileng oa ho etsa lihokelo tse kopaneng | |
| IEEE 802.3x: Taolo ea phallo | |
| IEEE 802.1ab: LLDP/LLDP-MED (Linka Layer Discovery Protocol) | |
| IEEE 802.1p: LAN Layer QoS/CoS Protocol Prioritization (Multicast | |
| mosebetsi oa ho sefa) | |
| IEEE 802.1q: Ts'ebetso ea Borokho ea VLAN | |
| IEEE 802.1x: Taolo ea Phihlello ea Moreki/Server le Protocol ea Netefatso | |
| IEEE 802.1d: STP; IEEE 802.1s: MSTP; IEEE 802.1w: RSTP | |
| PoE Protocol | IEEE802.3af (15.4W); IEEE802.3at (30W) |
| Maemo a Indasteri | EMI: FCC Karolo ea 15 CISPR (EN55032) sehlopha A |
| EMS: EN61000-4-2 (ESD), EN61000-4-4 (EFT), EN61000-4-5 (Surge) | |
| Tšabo: IEC 60068-2-27 | |
| Ho oa mahala: IEC 60068-2-32 | |
| Ho sisinyeha: IEC 60068-2-6 | |
| Network Medium | 10Base-T: Katse3, 4, 5 kapa ka holimo ho UTP(≤100m) |
| 100Base-TX: Cat5 kapa ka holimo ho UTP(≤100m) | |
| 1000Base-TX: Cat5 kapa ka holimo ho UTP(≤100m) Optical | |
| Multimode fiber: 1310nm, 2Km | |
| Fiber ea mokhoa o le mong: 1310nm, 20/40 Km; 1550nm, 60/80/100/120Km | |
| Tshireletso | |
| Setifikeiti sa Tšireletso | CE/FCC/RoHS |
| Tikoloho | |
| Tikoloho ea Mosebetsi | Mocheso oa ho sebetsa: -20 ~ 55°C |
| Mocheso oa polokelo: -40 ~ 85°C | |
| Mongobo o sebetsang: 10% ~ 90%, e sa fokotseng | |
| Mocheso oa polokelo: 5% ~ 90%, e sa fokotseng | |
| Bophahamo ba ho sebetsa: Boholo ba maoto a 10,000 | |
| Boima ba polokelo: Boholo ba maoto a 10,000 | |
| Pontsho | |
| Lipontšo tsa LED | PWR (phepelo ea motlakase) |
| SYS (Sistimi) | |
| 1-24 PoE & ACT (PoE) | |
| 1-24 Link & ACT (Link & Act) | |
| 25-28 Link (Sehokelo) | |
| 25-28 Act (Molao) | |
| Phetoho ea DIP | Seta bocha |
| Mechini | |
| Sebopeho sa Sebopeho | Boemo ba Sehlahisoa (L * W * H): 440 * 284 * 44mm |
| Pakete Dimension (L*W*H): 495*350*103mm | |
| NW: 3.5kg | |
| KGW: 4.25kg | |
| Packing Info | Carton MEAS: 592 * 510 * 375mm |
| Bongata ba ho paka: li-unit tse 5 | |
| Boima ba ho paka: 22.5KG | |
| Mosebetsi oa Software oa Layer 2 | |
| Tsamaiso ea Boema-kepe | Noble/Thibela Port |
| Speed, Duplex, MTU Setting | |
| Taolo-phallo | |
| Tlhahlobo ea Boitsebiso ba Boema-kepe | |
| Port Mirroring | E ts'ehetsa li-port mirroring ka bobeli |
| Moeli oa lebelo la Port | E ts'ehetsa taolo ea li-port-based input / output bandwidth |
| Ho Ikhetha Boema-kepe | Ts'ehetsa ho itšehla thajana ha koung ea downlink, 'me e ka buisana le boema-kepe ba uplink |
| Khatello ea Sefefo | E ts'ehetsa unicast e sa tsejoeng, multicast, multicast e sa tsejoeng, khatello ea sefefo sa mofuta oa phatlalatso |
| Khatello ea sefefo e ipapisitseng le taolo ea bandwidth le sefefo sa sefefo | |
| Khokahano ea Khokahanyo | Tšehetsa static manual aggregation |
| Tšehetsa LACP dynamic aggregation | |
| VLAN | Phihlello |
| Sekutu | |
| Hybrid | |
| Boema-kepe ba tšehetso, protocol, karohano ea VLAN e thehiloeng ho MAC | |
| Ts'ehetsa ngoliso ea VLAN e matla ea GVRP | |
| VLAN ea lentsoe | |
| MAC | Ts'ehetsa keketso e tsitsitseng, ho hlakoloa |
| Moeli oa ho ithuta aterese ea MAC | |
| Ts'ehetsa tlhophiso ea nako ea botsofali e matla | |
| Sefate se otlollang | Ts'ehetsa protocol ea sefate sa STP |
| E tšehetsa RSTP Rapid Spanning Tree Protocol | |
| E ts'ehetsa Protocol ea Lifate tse Hlahang ka Potlako ea MSTP | |
| Multicast | Ts'ehetsa keketso e tsitsitseng, ho hlakoloa |
| IGMP-snooping | |
| Tšehetsa MLD-Snooping | |
| Ts'ehetso ea v1/2/3 e matla ea li-multicast monitor | |
| DDM | Tšehetsa SFP/SFP+DDM |
| Mosebetsi o Atolositsoeng | |
| ACL | E ipapisitse le mohloli oa MAC, sebaka sa MAC, mofuta oa protocol, IP ea mohloli, moo u eang |
| IP, boema-kepe ba L4 | |
| QoS | E ipapisitse le sehlopha sa 802.1p (COS). |
| E ipapisitse le sehlopha sa DSCP | |
| Khethollo e ipapisitse le mohloli oa IP, sebaka sa IP, le nomoro ea boema-kepe | |
| Ts'ehetso ea SP, leano la ho hlophisa WRR | |
| Tšehetso ea tekanyo ea phallo moeli CAR | |
| LLDP | Ts'ehetsa protocol ea ho sibolla sehokelo sa LLDP |
| Litlhophiso tsa basebelisi | Kenya/hlakola basebelisi |
| Log | Ho kena ha basebelisi, ts'ebetso, boemo, liketsahalo |
| Khahlanong le tlhaselo | Tšireletso ea DOS |
| Ts'ehetsa ts'ireletso ea CPU le ho fokotsa sekhahla sa ho romella lipakete tsa CPU | |
| Tlamahano ea ARP (IP, MAC, PORT e tlamang) | |
| Setifikeiti | Ts'ehetsa netefatso ea boema-kepe ba 802.1x |
| Ts'ehetsa setifikeiti sa AAA | |
| Tlhahlobo ea marang-rang | Ts'ehetso ea ping, telnet, trace |
| Tsamaiso ea Tsamaiso | Ho seta sesebelisoa bocha, ho boloka / ho khutlisa, ho ntlafatsa taolo, ho hlophisa nako, joalo-joalo. |
| Mosebetsi oa tsamaiso | |
| CLI | Ts'ehetsa taolo ea mohala oa taelo ea serial port |
| SSH | Ts'ehetsa taolo ea hole ea SSHv1/2 |
| TELNET | Ts'ehetsa taolo ea hole ea telnet |
| WEB | Litlhophiso tsa Layer 2, Layer 2 le Layer 3 monitor |
| SNMP | SNMP V1/V2/V3 |
| Sefi sa tšehetso: ColdStart, WarmStart, LinkDown, LinkUp | |
| RMON | Tšehetsa RMON v1 |
| PoE | Ts'ehetsa phepelo ea motlakase ea PoE |
| Mesebetsi e meng | Tšehetsa DHCP Snooping, Option82, DHCP Server |
| Ts'ehetsa ho fumaneha ha ARP e matla | |
| Ts'ehetsa setifikeiti sa TACACS+ | |
| Ts'ehetsa setifikeiti sa DNS | |
| Ts'ehetsa litlhophiso tsa ts'ireletso ea koung | |
| Ts'ehetsa protocol ea MVR | |
| Ts'ehetsa ts'ebetso ea VCT ea ho lemoha cable | |
| Ts'ehetsa protocol ea UDLD |












