TH-G Series Layer2 Managed Ethernet Switch 2xGigabit SFP, 8×10/100/1000Base-T 4xGigabit Combo( RJ45/SFP) 24×10/100/1000Base-T Port
Gigabit Layer 2 Managed Switch e na le 8(24)x Gigabit Ethernet Ports le 2(4)x Gigabit SFP Ports tse ikamahanyang le mokhoa o felletseng kapa halofo ea duplex. Theknoloji ea ho ithuta ea aterese ea MAC ea Switch e nolofalletsa phetisetso ea data ntle le liphoso, ha mokhoa oa eona oa ho boloka le oa pele o thibela lipakete tse senyehileng hore li se ke tsa tlala marang-rang. Ho feta moo, sesebelisoa sena se na le ts'ebetso ea ho laola phallo e ka thibelang palo e kholo ea data hang-hang ho ama marang-rang.
Sesebelisoa se fana ka mesebetsi e tsoetseng pele ea taolo ea marang-rang joalo ka marang-rang a sa hlokeng letho, VLAN, cluster, QoS, taolo ea lebelo, setšoantšo sa boema-kepe, alamo ea phoso, le ntlafatso ea marang-rang ea firmware. E sebelisoa haholo maemong a phihlello ea Ethernet bakeng sa likhoebo tse nyane ho isa ho tse mahareng, li-cafe tsa marang-rang, lihotele, likolo le tse ling. Ka likarolo tsa eona tse felletseng, switjha ena e fana ka ts'ebetso e tšepahalang le e sebetsang ea marang-rang mme e thusa likhoebo ho fihlela khokahanyo e se nang moeli le phetiso ea data.
● Tšehetsa IEEE802.3/ IEEE802.3u/ IEEE802.3ab/IEEE802.3z, lebenkele-le-pele
● Mokhoa oa ho laola phallo: full-duplex e amohela IEEE 802.3x e tloaelehileng, halofo ea duplex e amohela maemo a khatello ea Morao
● E tšehetsa port auto flip (Auto MDI/MDIX)
● Sesupo sa phanele se beha leihlo boemo le ho thusa tlhahlobo ea ho hloleha
● E ts'ehetsa netefatso ea boema-kepe ba 802.1x, ts'ehetsa netefatso ea AAA, ts'ehetsa netefatso ea TACACS+
● Tšehetsa WEB, TELNET, CLI, SSH, SNMP, tsamaiso ea RMON
● Tšireletso ea Surge: General 4KV, Differential 2KV, ESD 8KV air, 6KV contact
| I/O Interface | ||
| Kenyeletso ya Matla | AC 100-240V, 50/60Hz | |
| Boema-kepe bo tsitsitseng | P/N | Boema-kepe bo tsitsitseng |
| TH-G0208M2-R | 8 * 10/ 100/ 1000Mbps Ethernet Port | |
| 2 * 1000Mbps SFP Port | ||
| 1* Console Port | ||
| TH-G0424M2-Z | Boema-kepe ba 24 x 10/ 100/ 1000Mbps | |
| 4 x 1000M Combo (RJ45/SFP) Port | ||
| 1 x RJ45 Console Port | ||
| Tshebetso | ||
| Bophahamo ba motlakase | 20Gbps (e sa thibeleng)/56Gbps | |
| Sekhahla sa ho fetisa Pakete | 14.88Mpps/41.66Mpps | |
| Pakete Buffer | 4M | |
| Bokhoni ba memori | 128MB | |
| Bokhoni ba Flash | 16MB | |
| Aterese ea MAC | 8K | |
| Lisebelisoa tsa VLAN | 4096 | |
| Sebopeho sa Jumbo | 9.6Kbytes | |
| Mokhoa oa ho fetisa | Boloka le ho ea pele | |
| MTBF | 100000 hora | |
| Standard | ||
| Protocol ea marang-rang | IEEE802.3: 10Base-T | |
| IEEE802.3u: 100Base-TX | ||
| IEEE802.3ab : 1000Base-TX | ||
| IEEE802.3z :1000Base- FX | ||
| IEEE 802.3x: Taolo ea phallo | ||
| IEEE 802.1ab : LLDP/LLDP- MED (Link Layer Discovery Protocol) | ||
| IEEE 802.1p: LAN Layer QoS/CoS Protocol Traffic Preoritization (Mosebetsi oa ho sefa ka bongata) | ||
| IEEE 802.1q: Ts'ebetso ea Borokho ea VLAN | ||
| IEEE 802.1x: Taolo ea Phihlello ea Moreki/Server le Protocol ea Netefatso | ||
| IEEE 802.3ad : Mokhoa o tloaelehileng oa ho etsa lihokelo tse kopaneng | ||
| IEEE 802.1d: STP | ||
| IEEE 802.1s: MSTP | ||
| IEEE 802.1w: RSTP | ||
| Maemo a Indasteri | EMI: FCC Karolo ea 15 CISPR (EN55032) sehlopha A | |
| EMS: EN61000-4-2 (ESD), | ||
| EN61000-4-5 (Surge) | ||
| Network Medium | ||
| 10Base-T: Cat3/4/5 kapa ka holimo ho UTP(≤100m) | ||
| 100Base-TX: Cat5 kapa ka holimo ho UTP(≤100m) | ||
| 1000Base-TX: Cat5 kapa ka holimo ho UTP (≤100m) | ||
| Litšobotsi tsa Optical | Mefuta e mengata: 850/ 1310nm (0-2KM) | |
| Mokhoa o le mong: 1310/ 1550/ 1490nm (0- 120KM) | ||
| Litifikeiti | ||
| Setifikeiti sa Tšireletso | CE, FCC, RoHS | |
| Tikoloho | ||
| Tikoloho ea Mosebetsi | Mocheso oa ho sebetsa: - 10 ~ 50.C | |
| Mocheso oa polokelo: -40 ~ 70.C | ||
| Mongobo o sebetsang: 10% ~ 90%, o sa fokotseheng | ||
| Mocheso oa polokelo: 5% ~ 90%, e sa fokotseng | ||
| Pontsho | ||
| Lipontšo tsa LED | PWR, SYS, Link, ACT | |
| Mechini | ||
| Sebopeho sa Sebopeho | Boholo ba lihlahisoa: 268 * 181 * 44mm | |
| Boholo ba sephutheloana: 312 * 262 * 84mm | ||
| Boima ba lihlahisoa: 1.01KG | ||
| Boima ba Sehlahisoa: 1.54KG | ||
| / | ||
| Boemo ba Sehlahisoa (L * W * H) : 440 * 284 * 44mm | ||
| Pakete ea boholo (L*W*H): 495*350*103mm | ||
| NW: 3.5kg | ||
| KGW: 4.25kg | ||
| Packing Info | MESE: 540 * 435 * 332mm | |
| Boholo ba ho paka: 10PCS | ||
| Boima ba ho paka: 16.4KG | ||
| / | ||
| Carton MEAS: 592 * 510 * 375mm | ||
| Bongata ba ho paka: li-unit tse 5 | ||
| Boima ba ho paka: 22.5KG | ||
| Mosebetsi oa Software oa Layer 2 | ||
| Tsamaiso ea Boema-kepe | Enable/ Ho tima Boema-kepe | |
| Speed, Duplex, MTU Setting | ||
| Phallo- taolo | ||
| Tlhahlobo ea Boitsebiso ba Boema-kepe | ||
| Port Mirroring | E ts'ehetsa li-port mirroring ka bobeli | |
| Moeli oa lebelo la Port | E ts'ehetsa taolo ea li-port-based input / output bandwidth | |
| Ho Ikhetha Boema-kepe | Ts'ehetsa ho itšehla thajana ha koung ea downlink, 'me e ka buisana le boema-kepe ba uplink | |
| Khatello ea Sefefo | E tšehetsa unicast e sa tsejoeng, multicast, multicast e sa tsejoeng, kgatello ya mofuta wa kgaso ya sefefo | |
| Khatello ea sefefo e ipapisitseng le taolo ea bandwidth le sefefo sa sefefo | ||
| Khokahano ea Khokahanyo | Tšehetsa static manual aggregation | |
| Tšehetsa LACP dynamic aggregation | ||
| VLAN | Phihlello | |
| TrunkHybrid | ||
| Boema-kepe ba tšehetso, protocol, karohano ea VLAN e thehiloeng ho MAC | ||
| Ts'ehetsa ngoliso ea VLAN e matla ea GVRP | ||
| VLAN ea lentsoe | ||
| MAC | Ts'ehetsa keketso e tsitsitseng, ho hlakoloa | |
| Moeli oa ho ithuta aterese ea MAC | ||
| Ts'ehetsa tlhophiso ea nako ea botsofali e matla | ||
| Sefate se otlollang | Ts'ehetsa protocol ea sefate sa STP | |
| E tšehetsa RSTP Rapid Spanning Tree Protocol | ||
| E ts'ehetsa Protocol ea Lifate tse Hlahang ka Potlako ea MSTP | ||
| Multicast | Ts'ehetsa keketso e tsitsitseng, ho hlakoloa | |
| IGMP - snooping | ||
| Tšehetsa MLD- Snooping | ||
| Ts'ehetso ea v1/2/3 e matla ea li-multicast monitor | ||
| DDM | Tšehetsa SFP/SFP+DDM | |
| ACL | E ipapisitse le mohloli oa MAC, sebaka sa MAC, mofuta oa protocol, IP ea mohloli, sebaka sa IP, boema-kepe ba L4 | |
| Qos | E ipapisitse le sehlopha sa 802.1p (COS). | |
| E ipapisitse le sehlopha sa DSCP | ||
| Khethollo e ipapisitse le mohloli oa IP, sebaka sa IP, le nomoro ea boema-kepe | ||
| Ts'ehetso ea SP, leano la ho hlophisa WRR | ||
| Tšehetso ea tekanyo ea phallo moeli CAR | ||
| LLDP | Ts'ehetsa protocol ea ho sibolla sehokelo sa LLDP | |
| Litlhophiso tsa basebelisi | Kenya/hlakola basebelisi | |
| Log | Ho kena ha basebelisi, ts'ebetso, boemo, liketsahalo | |
| Khahlanong le tlhaselo | Tšireletso ea DOS | |
| Ts'ehetsa ts'ireletso ea CPU mme e fokotsa sekhahla sa ho romella lipakete tsa cpu | ||
| Tlamahano ea ARP (IP, MAC, PORT e tlamang) | ||
| Setifikeiti | Tšehetsa 8 0 2 . 1 x netefatso ea koung | |
| Ts'ehetsa setifikeiti sa AAA | ||
| Tlhahlobo ea marang-rang | Ts'ehetso ea ping, telnet, trace | |
| Tsamaiso ea Tsamaiso | Ho seta sesebelisoa bocha, ho boloka / ho khutlisa, ho ntlafatsa taolo, ho hlophisa nako, joalo-joalo. | |
| CLI | Ts'ehetsa taolo ea mohala oa taelo ea serial port | |
| SSH | Ts'ehetsa taolo ea hole ea SSHv1/2 | |
| MACTELNET | Ts'ehetsa taolo ea hole ea telnet | |
| WEB | Litlhophiso tsa Layer 2, Layer 2 le Layer 3 monitor | |
| LLDP | Ts'ehetsa protocol ea ho sibolla sehokelo sa LLDP | |
| Litlhophiso tsa basebelisi | Kenya/hlakola basebelisi | |
| Log | Ho kena ha basebelisi, ts'ebetso, boemo, liketsahalo | |
| Khahlanong le tlhaselo | Tšireletso ea DOS | |
| Ts'ehetsa ts'ireletso ea CPU mme e fokotsa sekhahla sa ho romella lipakete tsa cpu | ||
| Tlamahano ea ARP (IP, MAC, PORT e tlamang) | ||
| Setifikeiti | Tšehetsa 8 0 2 . 1 x netefatso ea koung | |
| Ts'ehetsa setifikeiti sa AAA | ||
| Tlhahlobo ea marang-rang | Ts'ehetso ea ping, telnet, trace | |
| Tsamaiso ea Tsamaiso | Ho seta sesebelisoa bocha, ho boloka / ho khutlisa, ho ntlafatsa taolo, ho hlophisa nako, joalo-joalo. | |
| CLI | Ts'ehetsa taolo ea mohala oa taelo ea serial port | |
| SSH | Ts'ehetsa taolo ea hole ea SSHv1/2 | |
| TELNET | Ts'ehetsa taolo ea hole ea telnet | |
| WEB | Litlhophiso tsa Layer 2, Layer 2 le Layer 3 monitor | |
| SNMP
| SNMP V1/V2/V3 | |
| Sefi sa tšehetso: ColdStart, WarmStart, Link Down, Link Up | ||
| RMON | Tšehetsa RMON v1 | |
| Mesebetsi e meng | Tšehetsa DHCP Snooping, Option82 | |
| Ts'ehetsa ho fumaneha ha ARP e matla | ||
| Ts'ehetsa setifikeiti sa TACACS+ | ||
| Ts'ehetsa setifikeiti sa DNS | ||
| Ts'ehetsa litlhophiso tsa ts'ireletso ea koung | ||
| Ts'ehetsa protocol ea MVR | ||