TH-G0208M2-R Layer2 Layer2 Ethernet Switch 2xGigabit SFP, 8×10/100/1000Base-T

Nomoro ea Mohlala:TH-G0208M2-R

Lebitso:Todahika

  • E tšehetsa port auto flip (Auto MDI/ MDIX)
  • Sesupo sa phanele se beha leihlo boemo le ho thusa tlhahlobo ea ho hloleha

Lintlha tsa Sehlahisoa

Likaroloana

Ho Odara Boitsebiso

Litlhaloso

Boemo

Li-tag tsa Sehlahisoa

Tlhaloso ea Sehlahisoa

Gigabit Layer 2 Managed Switch support 8xGigabit Ethernet Ports + 2xGigabit SFP Ports, ka tsela e iketsang ikamahanya le duplex e felletseng kapa halofo ea duplex mode.Aterese ea MAC ea ho ithuta ka boithaopo e tiisa hore ho fetisoa ha data ntle le phoso, 'me mokhoa oa ho boloka le oa pele o thibela lipakete tse senyehileng hore li se ke tsa tlala marang-rang.Mosebetsi oa ho laola phallo o ka thibela phello ea palo e kholo ea data hang-hang marang-rang.

Letoto lena la li-switches le fana ka mesebetsi e tsoetseng pele ea tsamaiso ea marang-rang: marang-rang a sa hlokahaleng a marang-rang, VLAN, cluster, QoS, taolo ea lebelo, setšoantšo sa koung, alamo ea phoso le ntlafatso ea firmware ea inthaneteng, e sebelisoang haholo maemong a phihlello ea Ethernet joalo ka likhoebo tse nyane le tse mahareng, li-cafes tsa inthanete. , lihotele, likolo, joalo-joalo.

TH-8G0024M2P

  • E fetileng:
  • E 'ngoe:

  • ● Tšehetsa IEEE802.3/ IEEE802.3u/ IEEE802.3ab/IEEE802.3z, lebenkele-le-pele

    ● Mokhoa oa ho laola phallo: full-duplex e amohela IEEE 802.3x e tloaelehileng, halofo ea duplex e amohela maemo a khatello ea Morao

    E tšehetsa port auto flip (Auto MDI/ MDIX)

    ● Sesupo sa phanele se beha leihlo boemo le ho thusa tlhahlobo ea ho hloleha

    ● E ts'ehetsa netefatso ea boema-kepe ba 802.1x, ts'ehetsa netefatso ea AAA, ts'ehetsa netefatso ea TACACS+

    ● Tšehetsa WEB, TELNET, CLI, SSH, SNMP, tsamaiso ea RMON

    ● Tšireletso ea Surge: General 4KV, Differential 2KV, ESD 8KV air, 6KV contact

    KAROLO NO. TLHALOSO
    TH-G0208M2-R Layer2 Managed Ethernet Switch 2xGigabit SFP, 8×10/100/1000Base-T

    I/O Interface

    Kenyeletso ya Matla

    AC 100-240V, 50/60Hz

    Boema-kepe bo tsitsitseng

    8 * 10/100/1000Mbps Ethernet Port

    2 * 1000Mbps SFP Port

    1* Console Port

    Tshebetso

    Bophahamo ba motlakase

    20Gbps (e sa thibeleng)

    Sekhahla sa ho fetisa Pakete

    14.88Mpps

    Pakete Buffer

    4M

    Bokhoni ba memori

    128MB

    Bokhoni ba Flash

    16MB

    Aterese ea MAC

    8K

    Lisebelisoa tsa VLAN

    4096

    Sebopeho sa Jumbo

    9.6Kbytes

    Mokhoa oa ho fetisa

    Boloka le ho ea pele

    MTBF

    100000 hora

    Standard

    Protocol ea marang-rang

    IEEE802.3: 10Base-T

    IEEE802.3u: 100Base-TX

    IEEE802.3ab: 1000Base-TX

    IEEE802.3z :1000Base-FX

    IEEE 802.3x: Taolo ea phallo

    IEEE 802.1ab: LLDP/LLDP-MED (Protocol ea Layer Discovery Protocol)

    IEEE 802.1p: LAN Layer QoS/CoS Protocol Traffic Preoritization (Mosebetsi oa ho sefa ka bongata)

    IEEE 802.1q: Ts'ebetso ea Borokho ea VLAN

    IEEE 802.1x: Taolo ea Phihlello ea Moreki/Server le Protocol ea Netefatso

    IEEE 802.3ad: Mokhoa o tloaelehileng oa ho etsa lihokelo tse kopaneng

    IEEE 802.1d: STP

    IEEE 802.1s: MSTP

    IEEE 802.1w: RSTP

    Maemo a Indasteri

    EMI: FCC Karolo ea 15 CISPR (EN55032) sehlopha sa A

    EMS: EN61000-4-2 (ESD),

    EN61000-4-5 (Surge)

    Network Medium

    10Base-T: Cat3/4/5 kapa ka holimo ho UTP(≤100m)

    100Base-TX: Cat5 kapa ka holimo ho UTP(≤100m)

    1000Base-TX: Cat5 kapa ka holimo ho UTP (≤100m)

    Litšobotsi tsa Optical

    Mefuta e mengata: 850/1310nm (0-2KM)

    Mokhoa o le mong: 1310/1550/1490nm (0-120KM)

    Litifikeiti

    Setifikeiti sa Tšireletso

    CE, FCC, RoHS

    Tikoloho

    Tikoloho ea Mosebetsi

    Mocheso oa ho sebetsa: -10 ~ 50°C

    Mocheso oa polokelo: -40 ~ 70°C

    Mongobo o sebetsang: 10% ~ 90%, o sa fokotseheng

    Mocheso oa polokelo: 5% ~ 90%, e sa fokotseng

    Pontsho

    Lipontšo tsa LED

    PWR, SYS, Link, ACT

    Mechini

    Sebopeho sa Sebopeho

    Boholo ba lihlahisoa: 268 * 181 * 44mm

    Boholo ba sephutheloana: 312 * 262 * 84mm

    Boima ba lihlahisoa: 1.01KG

    Boima ba Sehlahisoa: 1.54KG

    Packing Info

    MESE: 540 * 435 * 332mm

    Boholo ba ho paka: 10PCS

    Boima ba ho paka: 16.4KG

    Mosebetsi oa Software oa Layer 2

    Tsamaiso ea Boema-kepe

    Noble/Thibela Port

    Speed, Duplex, MTU Setting

    Taolo-phallo

    Tlhahlobo ea Boitsebiso ba Boema-kepe

    Port Mirroring

    E ts'ehetsa li-port mirroring ka bobeli

    Moeli oa lebelo la Port

    E ts'ehetsa taolo ea li-port-based input / output bandwidth

    Ho Ikhetha Boema-kepe

    Ts'ehetsa ho itšehla thajana ha koung ea downlink, 'me e ka buisana le boema-kepe ba uplink

    Khatello ea Sefefo

    E tšehetsa unicast e sa tsejoeng, multicast, multicast e sa tsejoeng,

    kgatello ya mofuta wa kgaso ya sefefo

    Khatello ea sefefo e ipapisitseng le taolo ea bandwidth le sefefo sa sefefo

    Khokahano ea Khokahanyo

    Tšehetsa static manual aggregation

    Tšehetsa LACP dynamic aggregation

    VLAN

    Phihlello

    Sekutu

    Hybrid

    Boema-kepe ba tšehetso, protocol, karohano ea VLAN e thehiloeng ho MAC

    Ts'ehetsa ngoliso ea VLAN e matla ea GVRP

    VLAN ea lentsoe

    MAC

    Ts'ehetsa keketso e tsitsitseng, ho hlakoloa

    Moeli oa ho ithuta aterese ea MAC

    Ts'ehetsa tlhophiso ea nako ea botsofali e matla

    Sefate se otlollang

    Ts'ehetsa protocol ea sefate sa STP

    E tšehetsa RSTP Rapid Spanning Tree Protocol

    E ts'ehetsa Protocol ea Lifate tse Hlahang ka Potlako ea MSTP

    Multicast

    Ts'ehetsa keketso e tsitsitseng, ho hlakoloa

    IGMP-snooping

    Tšehetsa MLD-Snooping

    Ts'ehetso ea v1/2/3 e matla ea li-multicast monitor

    DDM

    Tšehetsa SFP/SFP+DDM

    ACL

    E ipapisitse le mohloli oa MAC, sebaka sa MAC, mofuta oa protocol, IP ea mohloli, sebaka sa IP, boema-kepe ba L4

    Qos

    E ipapisitse le sehlopha sa 802.1p (COS).

    E ipapisitse le sehlopha sa DSCP

    Khethollo e ipapisitse le mohloli oa IP, sebaka sa IP, le nomoro ea boema-kepe

    Ts'ehetso ea SP, leano la ho hlophisa WRR

    Tšehetso ea tekanyo ea phallo moeli CAR

    LLDP

    Ts'ehetsa protocol ea ho sibolla sehokelo sa LLDP

    Litlhophiso tsa basebelisi

    Kenya/hlakola basebelisi

    Log

    Ho kena ha basebelisi, ts'ebetso, boemo, liketsahalo

    Khahlanong le tlhaselo

    Tšireletso ea DOS

    Ts'ehetsa ts'ireletso ea CPU mme e fokotsa sekhahla sa ho romella lipakete tsa cpu

    Tlamahano ea ARP (IP, MAC, PORT e tlamang)

    Setifikeiti

    Ts'ehetsa netefatso ea boema-kepe ba 802.1x

    Ts'ehetsa setifikeiti sa AAA

    Tlhahlobo ea marang-rang

    Ts'ehetso ea ping, telnet, trace

    Tsamaiso ea Tsamaiso

    Ho seta sesebelisoa bocha, ho boloka / ho khutlisa, ho ntlafatsa taolo, ho hlophisa nako, joalo-joalo.

    CLI

    Ts'ehetsa taolo ea mohala oa taelo ea serial port

    SSH

    Tšehetsa SSHv1/2 taolo e holeTELNET

    Ts'ehetsa taolo ea hole ea telnet

    WEBANG

    Litlhophiso tsa Layer 2, Layer 2 le Layer 3 monitor

    LLDP

    Ts'ehetsa protocol ea ho sibolla sehokelo sa LLDP

    Litlhophiso tsa basebelisi

    Kenya/hlakola basebelisi

    Log

    Ho kena ha basebelisi, ts'ebetso, boemo, liketsahalo

    Khahlanong le tlhaselo

    Tšireletso ea DOS

    Ts'ehetsa ts'ireletso ea CPU mme e fokotsa sekhahla sa ho romella lipakete tsa cpu

    Tlamahano ea ARP (IP, MAC, PORT e tlamang)

    Setifikeiti

    Ts'ehetsa netefatso ea boema-kepe ba 802.1x

    Ts'ehetsa setifikeiti sa AAA

    Tlhahlobo ea marang-rang

    Ts'ehetso ea ping, telnet, trace

    Tsamaiso ea Tsamaiso

    Ho seta sesebelisoa bocha, ho boloka / ho khutlisa, ho ntlafatsa taolo, ho hlophisa nako, joalo-joalo.

    CLI

    Ts'ehetsa taolo ea mohala oa taelo ea serial port

    SSH

    Ts'ehetsa taolo ea hole ea SSHv1/2

    TELNET

    Ts'ehetsa taolo ea hole ea telnet

    WEBANG

    Litlhophiso tsa Layer 2, Layer 2 le Layer 3 monitor

    SNMP

    SNMP V1/V2/V3

    Sefi sa tšehetso: ColdStart, WarmStart, LinkDown, LinkUp

    RMON

    Tšehetsa RMON v1

    Mesebetsi e meng

    Tšehetsa DHCP Snooping, Option82

    Ts'ehetsa ho fumaneha ha ARP e matla

    Ts'ehetsa setifikeiti sa TACACS+

    Ts'ehetsa setifikeiti sa DNS

    Ts'ehetsa litlhophiso tsa ts'ireletso ea koung

    Ts'ehetsa protoco ea MVR

    Boemo

    Ngola molaetsa wa hao mona mme o re romele wona